DesignJet 750 and 755 Error Codes

DesignJet 750 & 755 Error Codes
010001 error – Window sensor defective, front panel required
010020 error – ROM test failure, possible main PCA
010021 error – DRAM failure replace main PCA
010022 error – Swath RAM failure, replace main PCA
010023 error – EEROM failure, clear EEROM / Replace main PCA
010024 error – Pen interface failure, replace main PCA
010030 error – Internal communication error
010032 error – Internal communication error
010033 error – Internal communication error
010034 error – Internal communication error
010040 error – X-Axis servo error
010041 error – Y-Axis servo error
010050 error – Defective Postscript SIMM
010060 error – Primer motor failure
010080 error – RS-232 data overflow
020001 error – Memory error, try turning off queuing & adding more RAM
020002 error – Memory error, try turning off queuing & adding more RAM
02002x error – Firmware error, replace Postscript SIMM
030010 error – Service station error
04xxxx error – MIO error, check MIO setup
040601 error – Incorrect MIO card
05xxxx error – MIO system error
06030A error – Mark Position not found, possible carriage assy
06030B error – Bad ambient temperature
060308 error – Problem with pen voltage
060309 error – Problem with pen voltage
070000 error – Unable to calibrate drop detect
070005 error – Calibration problem
070006 error – Calibration problem
070007 error – Calibration problem
070008 error – Calibration problem
070010 error – False drops detected, check your power supply is not noisy
070020 error – Drop detect error
070030 error – Drop detect error
070100 error – Firmware error
0000D8 error – Firmware error
080001 error – Postscript error