DesignJet T730 & T830 Error Codes
0001-0082  Main PCA  Battery or Real time clock ran down
0004-0001 Print bundle PCA  MALFUNCTION_ERROR_STATUS_OR_STATE
0008-0001  Candela Control Panel MALFUNCTION_ERROR_STATUS_OR_STATE
0009-0000  Scanner Generic failure
0009-0101  Scanner bundle PCA  MALFUNCTION_ERROR_STATUS_OR_STATE
0009-0174  Scanner bundle PCA NVM_ISSUE
0009-0201  Scanner motor MALFUNCTION_ERROR_STATUS_OR_STATE
0009-0301 Scanner bar MALFUNCTION_ERROR_STATUS_OR_STATE
0009-0401  Scanner slider MALFUNCTION_ERROR_STATUS_OR_STATE
0021-0001  Service station assy MALFUNCTION_ERROR_STATUS_OR_STATE
0021-0017 Service station assy MOVEMENT_BLOCKED
0021-0132  Prime pump CURRENT_TOO_LOW
0021-0161  Prime pump MOTOR_FAULT
0021-0180  Prime pump AIR LEAK
0024-0000 Ink Blockage Last 4 bits interpreted as 0=working 1=not working, order is KCMY
0026-0061  ISS 61. MOTOR_FAULT
0026-0100  ISS Opto Trip Sensors Last 4 bits interpreted as 0=working 1=not working, order is KCMY
0026-0200  ISS Bongo Malfunction Last 4 bits interpreted as 0=working 1=not working, order is KCMY
0041-0017  Paper motor MOVEMENT_BLOCKED
0042-0117  Carriage motor MOVEMENT_BLOCKED
0043-0017 Pick motor MOVEMENT_BLOCKED
0045-0017 Rewinder motor MOVEMENT_BLOCKED
0051-0101 Top/Front door sensor MALFUNCTION_ERROR_STATUS_OR_STATE
0051-0201 PHA door sensor MALFUNCTION_ERROR_STATUS_OR_STATE
0051-0301  Ink door sensor  MALFUNCTION_ERROR_STATUS_OR_STATE
0053-0101  OOP Sensor  MALFUNCTION_ERROR_STATUS_OR_STATE
0053-0201  Output tray sensor  MALFUNCTION_ERROR_STATUS_OR_STATE
0059-0190 Main PCA NVM or NVM Backup PCA  NVM_CONFLICT_MAIN_VS_BACKUP
0059-0191  Main PCA NVM or NVM Backup PCA NVM_DEFAULT_IN_BOTH_MAIN_AND_BACKUP
0059-0289  NVM Backup PCA  BACKUP_NVM_MISSING
0085-0101  Feed index PCA  MALFUNCTION_ERROR_STATUS_OR_STATE
0085-0201  Feed encoder PCA  MALFUNCTION_ERROR_STATUS_OR_STATE
0087-0001  Encoder strip  MALFUNCTION_ERROR_STATUS_OR_STATE
0153-0302  Multisheet tray sensor CHECK_FAILURE_PRESENCE_INITIALIZATION_ERROR
0359-0073  Main PCA NVM  DERIVATIVE_SETTING
0721-0078  Service station assy  UPDATE_OR_MAINTENANCE_NEEDED
0759-0073  Main PCA NVM  DERIVATIVE_SETTING
0942-0188  Carriage motor Carriage homing problem
0955-0050  Carriage Zim sensor SV  UNABLE_TO_READ_GET_VALUE>0000-0059  Unknown Service Part  MOTOR_SERVO_SHUTDOWN
0021-0059  Service station assy MOTOR_SERVO_SHUTDOWN
0024-1000  Leakage or Missing Ctg Last 4 bits interpreted as 0=working 1=not working, order is KCMY
0024-1100  OOI Altered Ctg Last 4 bits interpreted as 0=working 1=not working, order is KCMY
0026-0075  ISS  Generic Ink supply failure
0026-0085  ISS  Empty supplies
0026-0092  ISS Too early empty supplies
0026-0093 ISS  EE failure
0026-0094 ISS  Non OOI cartridge failure
0027-0001  Printhead “Generic PHA error”
0027-0002  Printhead “PHA error: not responding at all”
0027-0003  Printhead “PHA error: CSIO xfer completed incorrectly”
0027-0004  Printhead “PHA error: Watchdog fault”
0027-0005  Printhead “PHA error: Auric data reset”
0027-0006  Printhead “PHA error: Unrecognized pen type”
0027-0007  Printhead “PHA error: LVDS error”
0027-0008  Printhead “PHA error: Pen ID invalid”
0027-0009  Printhead “PHA error: Pen ID b/f”
0027-0010  Printhead “PHA error: Pen ID write failure”
0027-0011  Printhead “PHA error: Bad DTSR”
0027-0012  Printhead “PHA error: Temp out of range”
0027-0013  Printhead “PHA error: Temp out of range”
0027-0014  Printhead “PHA error: TSR fault”
0027-0015  Printhead “PHA error: Pen stuck cold”
0027-0016  Printhead “PHA error: Pen not heating”
0027-0017  Printhead “PHA error: VDD short”
0027-0018  Printhead “PHA error: VDD short”
0027-0019  Printhead “PHA error: VDD expected on”
0027-0020  Printhead “PHA error: VPP short”
0027-0021  Printhead “PHA error: VPP short”
0027-0022  Printhead “PHA error: VPP short”
0027-0023  Printhead “PHA error: VPP short”
0027-0024 Printhead “PHA error: VPP short test”
0027-0025  Printhead “PHA error: VPP short test”
0027-0026  Printhead “PHA error: VPP expected off”
0027-0027  Printhead “PHA error: VPP out of range”
0027-0028  Printhead “PHA error: VPP out of range”
0027-0029  Printhead “PHA error: VPP out of range”
0027-0030  Printhead “PHA error: VPP out of range”
0027-0031  Printhead “PHA error: VPP out of range”
0027-0032  Printhead “PHA error: VPP out of range”
0027-0033  Printhead “PHA error: VPP bleed failed”
0027-0034  Printhead “PHA error: VDD check timeout”
0027-0035  Printhead “PHA error: VPP check timeout”
0027-0036  Printhead “PHA error: VPP bleed fuse”
0027-0037  Printhead “PHA error: VPP bleed fuse”
0027-0038  Printhead “PHA error: VDD too many ignored”