0001-0082 Main PCA Battery or Real time clock ran down |
0004-0001 Print bundle PCA MALFUNCTION_ERROR_STATUS_OR_STATE |
0008-0001 Candela Control Panel MALFUNCTION_ERROR_STATUS_OR_STATE |
0009-0000 Scanner Generic failure |
0009-0101 Scanner bundle PCA MALFUNCTION_ERROR_STATUS_OR_STATE |
0009-0174 Scanner bundle PCA NVM_ISSUE |
0009-0201 Scanner motor MALFUNCTION_ERROR_STATUS_OR_STATE |
0009-0301 Scanner bar MALFUNCTION_ERROR_STATUS_OR_STATE |
0009-0401 Scanner slider MALFUNCTION_ERROR_STATUS_OR_STATE |
0021-0001 Service station assy MALFUNCTION_ERROR_STATUS_OR_STATE |
0021-0017 Service station assy MOVEMENT_BLOCKED |
0021-0132 Prime pump CURRENT_TOO_LOW |
0021-0161 Prime pump MOTOR_FAULT |
0021-0180 Prime pump AIR LEAK |
0024-0000 Ink Blockage Last 4 bits interpreted as 0=working 1=not working, order is KCMY |
0026-0061 ISS 61. MOTOR_FAULT |
0026-0100 ISS Opto Trip Sensors Last 4 bits interpreted as 0=working 1=not working, order is KCMY |
0026-0200 ISS Bongo Malfunction Last 4 bits interpreted as 0=working 1=not working, order is KCMY |
0041-0017 Paper motor MOVEMENT_BLOCKED |
0042-0117 Carriage motor MOVEMENT_BLOCKED |
0043-0017 Pick motor MOVEMENT_BLOCKED |
0045-0017 Rewinder motor MOVEMENT_BLOCKED |
0051-0101 Top/Front door sensor MALFUNCTION_ERROR_STATUS_OR_STATE |
0051-0201 PHA door sensor MALFUNCTION_ERROR_STATUS_OR_STATE |
0051-0301 Ink door sensor MALFUNCTION_ERROR_STATUS_OR_STATE |
0053-0101 OOP Sensor MALFUNCTION_ERROR_STATUS_OR_STATE |
0053-0201 Output tray sensor MALFUNCTION_ERROR_STATUS_OR_STATE |
0059-0190 Main PCA NVM or NVM Backup PCA NVM_CONFLICT_MAIN_VS_BACKUP |
0059-0191 Main PCA NVM or NVM Backup PCA NVM_DEFAULT_IN_BOTH_MAIN_AND_BACKUP |
0059-0289 NVM Backup PCA BACKUP_NVM_MISSING |
0085-0101 Feed index PCA MALFUNCTION_ERROR_STATUS_OR_STATE |
0085-0201 Feed encoder PCA MALFUNCTION_ERROR_STATUS_OR_STATE |
0087-0001 Encoder strip MALFUNCTION_ERROR_STATUS_OR_STATE |
0153-0302 Multisheet tray sensor CHECK_FAILURE_PRESENCE_INITIALIZATION_ERROR |
0359-0073 Main PCA NVM DERIVATIVE_SETTING |
0721-0078 Service station assy UPDATE_OR_MAINTENANCE_NEEDED |
0759-0073 Main PCA NVM DERIVATIVE_SETTING |
0942-0188 Carriage motor Carriage homing problem |
0955-0050 Carriage Zim sensor SV UNABLE_TO_READ_GET_VALUE>0000-0059 Unknown Service Part MOTOR_SERVO_SHUTDOWN |
0021-0059 Service station assy MOTOR_SERVO_SHUTDOWN |
0024-1000 Leakage or Missing Ctg Last 4 bits interpreted as 0=working 1=not working, order is KCMY |
0024-1100 OOI Altered Ctg Last 4 bits interpreted as 0=working 1=not working, order is KCMY |
0026-0075 ISS Generic Ink supply failure |
0026-0085 ISS Empty supplies |
0026-0092 ISS Too early empty supplies |
0026-0093 ISS EE failure |
0026-0094 ISS Non OOI cartridge failure |
0027-0001 Printhead “Generic PHA error” |
0027-0002 Printhead “PHA error: not responding at all” |
0027-0003 Printhead “PHA error: CSIO xfer completed incorrectly” |
0027-0004 Printhead “PHA error: Watchdog fault” |
0027-0005 Printhead “PHA error: Auric data reset” |
0027-0006 Printhead “PHA error: Unrecognized pen type” |
0027-0007 Printhead “PHA error: LVDS error” |
0027-0008 Printhead “PHA error: Pen ID invalid” |
0027-0009 Printhead “PHA error: Pen ID b/f” |
0027-0010 Printhead “PHA error: Pen ID write failure” |
0027-0011 Printhead “PHA error: Bad DTSR” |
0027-0012 Printhead “PHA error: Temp out of range” |
0027-0013 Printhead “PHA error: Temp out of range” |
0027-0014 Printhead “PHA error: TSR fault” |
0027-0015 Printhead “PHA error: Pen stuck cold” |
0027-0016 Printhead “PHA error: Pen not heating” |
0027-0017 Printhead “PHA error: VDD short” |
0027-0018 Printhead “PHA error: VDD short” |
0027-0019 Printhead “PHA error: VDD expected on” |
0027-0020 Printhead “PHA error: VPP short” |
0027-0021 Printhead “PHA error: VPP short” |
0027-0022 Printhead “PHA error: VPP short” |
0027-0023 Printhead “PHA error: VPP short” |
0027-0024 Printhead “PHA error: VPP short test” |
0027-0025 Printhead “PHA error: VPP short test” |
0027-0026 Printhead “PHA error: VPP expected off” |
0027-0027 Printhead “PHA error: VPP out of range” |
0027-0028 Printhead “PHA error: VPP out of range” |
0027-0029 Printhead “PHA error: VPP out of range” |
0027-0030 Printhead “PHA error: VPP out of range” |
0027-0031 Printhead “PHA error: VPP out of range” |
0027-0032 Printhead “PHA error: VPP out of range” |
0027-0033 Printhead “PHA error: VPP bleed failed” |
0027-0034 Printhead “PHA error: VDD check timeout” |
0027-0035 Printhead “PHA error: VPP check timeout” |
0027-0036 Printhead “PHA error: VPP bleed fuse” |
0027-0037 Printhead “PHA error: VPP bleed fuse” |
0027-0038 Printhead “PHA error: VDD too many ignored” |