Designjet 750 & Designjet 755 Error Codes

  • 010001 error – Window sensor defective, front panel required
  • 010020 error – ROM test failure, possible main PCA
  • 010021 error – DRAM failure replace main PCA
  • 010022 error – Swath RAM failure, replace main PCA
  • 010023 error – EEROM failure, clear EEROM / Replace main PCA
  • 010024 error – Pen interface failure, replace main PCA
  • 010030 error – Internal communication error
  • 010032 error – Internal communication error
  • 010033 error – Internal communication error
  • 010034 error – Internal communication error
  • 010040 error – X-Axis servo error
  • 010041 error – Y-Axis servo error
  • 010050 error – Defective Postscript SIMM
  • 010060 error – Primer motor failure
  • 010080 error – RS-232 data overflow
  • 020001 error – Memory error, try turning off queuing & adding more RAM
  • 020002 error – Memory error, try turning off queuing & adding more RAM
  • 02002x error – Firmware error, replace Postscript SIMM
  • 030010 error – Service station error
  • 04xxxx error – MIO error, check MIO setup
  • 040601 error – Incorrect MIO card
    05xxxx error – MIO system error
  • 06030A error – Mark Position not found, possible carriage assy
  • 06030B error – Bad ambient temperature
  • 060308 error – Problem with pen voltage
  • 060309 error – Problem with pen voltage
  • 070000 error – Unable to calibrate drop detect
  • 070005 error – Calibration problem
  • 070006 error – Calibration problem
  • 070007 error – Calibration problem
  • 070008 error – Calibration problem
  • 070010 error – False drops detected, check your power supply is not noisy
  • 070020 error – Drop detect error
  • 070030 error – Drop detect error
  • 070100 error – Firmware error
  • 0000D8 error – Firmware error
  • 080001 error – Postscript error

 

Message us now