01.0:03 error –  Error Impact 12C Channel
01.0:10 error –  Problem With The Gamut PCI PCA
01.1:10 error –  Problem Wuth The PrintMech PCA
01.2:10 error –  ISS PCA Faulty – Humidity Sensor Out Of Scale Or NVM Backup Failure
02:10 error –  Encoder Seems To Be Wrong
02.1:10 error –  Problem With The Carriage PCA
03:10 error –  Problem With The Power Supply Unit
05.1:10 error –  CPU Fan Is Stoppede Or Burnt
05.3:10 error –  Main Memory Size Failure
06:03 error –  NVM File Has Bad CRC
06:10 error –  Main NVM Failure – Not Detected, Read/Write Failed Or Readback Error
07:10 error –  Aerosol Fan Drive Burnt
08:10 error –  Problem With Front Panel
1:10 error –  Trailing Cable Does Not Seem To Be Detected
13.n:10 error –  Problem Starting Acumen Supplies
21:03 error –  Service Station Servo Shutdown
21:12 error –  Fail Moving Service Station
21:13 error –  Problem With The Service Station
23:10 error –  Problem With The APS
24:03 error –  Ink Setup faiure(Ink Supply Tubes Purge Failed)
24:10 error –  Broken Bag Detected in Ink Cartridge
26.0:01 error –  Bad Contact Detected In ISS Slot – 0 Floater
26.1:01 error –  Bad Contact Detected In ISS Slot 1 Floater
26.2:01 error –  Bad Contact Detected In ISS Slot 2 Floater
26.3:01 error –  Bad Contact Detected In ISS Slot 3 Floater
26.n:10 error –  Order Of Ink Supplies Incorrect
26:14 error –  A Wrong Ink Cartridge Has Been Detected
27:03 error –  An Error Has Occurred In Printhead Detection
27:14 error –  A Wrong Printhead Has Been Detected
29.0:01 error –  Printhead Cleaner Not Inserted Correctly In Slot 1
29.1:01 error –  Printhead Cleaner Not Inserted Correctly In Slot 2
29.2:01 error –  Printhead Cleaner Not Inserted Correctly In Slot 3
29.3:01 error –  Printhead Cleaner Not Inserted Correctly In Slot 4
29.4:01 error –  Printhead Cleaner Not Inserted Correctly In Slot 5
29.5:01 error –  Printhead Cleaner Not Inserted Correctly In Slot – 6
29.6:01 error –  Printhead Cleaner Not Inserted Correctly In Slot 7
29.7:01 error –  Printhead Cleaner Not Inserted Correctly In Slot 8
41:03   error –  Electrical Current Limit In Media-Axis Motor
41:10   error –  Electrical Fault In Media-Axis Motor
42:03   error –  Elecrtical Current Limit In Scan-Axis Motor
42:10   error –  Electrical Fault In Scan-Axis Motor
43:10   error –  Vacuum Fan Has Stopped Functioning
44:10   error –  Problem With The Aerosol Fan
44:11   error –  Aerosol Fan Not Connected
51:10   error –  Window Sensor Failure
51.1:10   error –  PHC Access Door Sensor Failure
52:10   error –  Drop Detector Switch On/Off Failure
53:10   error – Media Sensor Failure
54:10   error – Media Lever Sensor Failure
55:10   error – Problem With The Line Sensor
56:03   error – Analog Encoder Calibration Failed
56:10   error – Analog Encoder Calibration Failed
61:01   error – The File Format Is Incorrect And The Printer Cannot Process The Job
61:04.1   error – The Postscript Fonts Are Missing. Upgrade The Firmware
61:08.1   error – The File Cannot Be Printed Because It Is Password Protected
63:04  error – Input/Output Problem Through The Network Card
64:04  error – Input/Output Problem Through The USB Port Request a repair estimate
65:04   error – Input/Output Problem Through An Unknown Port
66:08   error – Cannot Print File On Current Paper Type. The Paper Type Has Changed Since The File Was Sent
67:04  error – Input/Output Problem Through a Fireware Port
68:03 error – Non-critical permanent data was lost. This does not prevent the printer working, only that internal life counters will not be recorded untill the printer is restarted
71:03 error – Out of memory failure
71:04 error – Out of memory failure
71:19 error – Defult serial Number found in the main and back uo NVM. It seems that both the Ink Supply and Hard Disk Drive have been replaced together
72:04 error – Generic Firmware error
73:03 error – Servo error
74:00 error – Failed getting part number/serial number
74:01 error – Error uploading firmware
74:04 error – Old vacuum fan detected – upgrade the firmware
76:03 error – Out of disk space – data was lost
77:04 error – Embedded web server internal software error
79:03 error – Generic firmware error
79:04 error – Generic firmware error
79.1:04 error – CDS server lost connection with client
81:01 error – Paper servo shutdown
81:03 error – It was impossible to correctly stop the servo before setting the encoder position
81:10 error – Fail starting paper motor
85:03 error – Problem finding the drive roller zero
86:01 error – Carriage servo shutdown
86:03 error – Scan-axis lenght test failure
86:10 error – Initialising scan-axis motor failure
86:11 error – Scan-axis length too short
91:10 error – Repeated printhead issue
93:11 error – Unable to pressurise the IDS
98:02 error – Switching to lower performance due to printhead quality