010020 error – The CheckSum Read On The Flash SIMM Is InCorrect |
010021 error – The Base DRAM Or The RAM SIMM Tests Failed |
010022 error – The SWATH RAM Test Failed |
010023 error – A Fuse On The Main PCA Has Blown |
010025 error – Problem Initializing The Encoder Pulse Generator |
010030 error – One Of The Two Interconnect Boards Not Detected |
010031 error – The Printhead Primitive Driver ASIC Test Failed |
010032 error – Fan Test Failed – Current Not Detected In One Or Both Fans |
010033 error – The DC Motor ASIC Test Failed |
010034 error – One Of The DC Motor Has Failed |
010035 error – One Of The Stepper Motors Has Failed |
010036 error – ADC Test Failure In The Main PCA |
010037 error – ADC Test Failure In The Carriage PCA> |
010038 error – A Printhead Voltage Could Not Be Set – Main PCA Failure |
010039 error – A Printhead Voltage Could Not Be Set – Carriage PCA Failure |
010040 error – The Amnient Temperture Measured Is Out Of The Normal Range |
010041 error – Problem In Setting The Printhead Voltage |
010042 error – The Status Of One Of The Optical Sensors Is Not Stable When It Should Be |
010100 error – Error Reading In The EEROM |
010101 error – An Action Outside The EEROM Limits Has Been Performed |
010102 error – Physical EEROM Write And/Or Write Operations Failed. The EEROM Data That Is Written Does Not Match The Data That Is Read |
010110 error – The Content Of The Permanent Configuration Area Of The EEROM Is Not Valid When The Printer Is initialised In Service Mode |
010111 error – The Content Of The User Configuration Area EEROM Is Not Valid When The Printer Is initialised |
010120 error – The Content Of The Permanent Configuration Area Of The EERom Is Not Valid When Printer Is initialised In Normal Mode |
010121 error – One Of The Banks Of The User Area Was Corrupted While Writing Or Reading In That Area |
020000 error – Error In Finding The Primer Home Position |
020001 error – Error In Finding The Elevator Home Position |
020002 error – Error In Finding The Refill Arm Home Position |
020003 error – Error In Finding The refill Stepper Motor Home Position |
020004 error – Error In Finding The Service Station Home Position |
020005 error – Elevator Has A Problem Reaching A Desired Position |
020006 error – The Refill Position In The Y-axis In Not Calibrated |
020010 error – Problem With Fine Movement of The Y-Axis Motor |
020011 error – Error During Initialization Of The Y-Axis |
040xxx error – MIO Card Error |
040601 error- The MIO Card Does Not Support The MIO – 6 Protocol Cards With Vision – 5 Or Below Can Not Be Used With The Plotter. Version – 5.1 Cards Behave As Expected But Does Not Support PML Intructions |
050000 error – The Line Sensor Has Problems Finding The Mark Encoder |
060000 error – The Line Sensor Is Not Functioning Properly Because There Is To Much Ambient Light |
060200 error – Incompatible Firmware And Carriage PCA |
060399 error – Incompatible Firmware And Line Sensor |
07xxxx error – Firmware Error |
08xxxx error – PostScript Error |
080001 error – Hard Disk Drive Installed Without PostScript |
09xxxx error – Problem With The Hard Disk |
09004 error – PostScript Installed Without The Hard Disk Drive |